TECHNICAL SERVICE DATA
36
PDE07K*SE 230/2083.3 53 27 120 173 72 15 24 144400 42.0
PDE09K*SE 230/2083.6 52 28 117 155 55 15 21 142420 36.0
PDE12K*SE 230/2085.5 53 27 123 163 60 11 18 144439 33.0
PDE15K*SE 230/2087.0 49 31 133 184 61 11 31 133489 48.0
PDE07R*SE 265 2.9 53 27 115 150 65 12 23 158 390 35.0
PDE09R*SE 265 3.3 55 25 119 165 65 14 27 138 410 35.0
PDE12R*SE 265 4.6 52 28 126 167 55 722 140440 36.0
PDE15R*SE 265 6.4 49 31 134 166 55 13 26 132 470 42.0
PDH07K*SE 230/2083.2 55 25 117 165 71 18 19 151404 37.0
PDH09K*SE 230/2083.6 53 27 120 165 67 18 25 140420 35.0
PDH12K*SE 230/2085.4 53 27 125 177 65 14 22 140460 42.0
PDH15K*SE 230/2086.7 53 27 135 195 66 17 35 136 510 39.0
PDH07R*SE 265 2.8 55 25 118 168 65 15 22 155 400 38.0
PDH09R*SE 265 3.3 55 25 118 166 70 14 20 145 420 33.0
PDH12R*SE 265 5.2 53 27 129 170 67 14 25 145 470 40.0
PDH15R*SE 265 6.3 50 30 130 183 60 10 30 140 515 42.0
¹Test Conditions: 80º F, Room Air Temperature with 50% Relative Humidity, and 95º F, Outdoor Air Temperature with 40% Relative Humidity
*Denotes Heater KW - Number Varies
Refrigerant
Charge
Amps R-410A - Oz.
Suction Line
Temperature
º F
Super Heat
º F
Sub-Cooling
º F
OPERATING
PRESSURES
SuctionDischarge
SERVICE DATA
Cooling¹
INDOOR COIL
TEMPERATURE
º F
Discharge Line
Temperature
º F
Supply Air
Temperature
Drop
OUTDOOR COIL
TEMPERATURE
º F
Voltage
ELECTRICAL
RATINGS