Propane Tanks
Propane Hoses
We listed the total BTU content so you could determine approximately how long a heater or any other
appliance would last. For example, if you operate a 150,000 BTU heater on 2-100 lb tanks the heater should
operate over 14 hours, however, only 90% (approximate) of the contents can be used, so the heater will
operate 13+ hours.
Part No. Description Where Used
2510LH 1/4" X 10' w/Left Hand Sure Flame Torches,
9/16" x 18 fittings L.B. White Heaters
2510LHFTG Fitting to connect 2510LH or 2525 LH hoses together
2510 1/4" x 10' w/1/4" MPT 3500FA, 250, 250A, BLP375
x 1/4" Female Flair Swivel TC250, TC275
2525 1/4" x 25' w/1/4" MPF Same as above
x 1/4" Female Flair Swivel
2525LH 1/4 x 25 w/Left Hand Torches
2525FTG Fitting to connect 2510s or 2525 together
3810 3/8" x 10' w/3/8" MPT
x 3/8" Female Flair Swivel BLP80, BLP150,150FA, 80FA,150FAS
381050 3/8" X 10' w/3/8" MPT BLP155
x 1/2" Female Swivel
382550 3/8 x 25 1/2 FFIR swivel insert
3825 3/8" X 25' w/3/8" MPT Optional Hose for LP Heaters
3/8" Female Flair Swivel up to150,000 BTU's
3850 3/8 x 50 x 3/8 MPT
3810FTG Fitting to connect 3810s, 3825s or 3850s together
5010 1/2 x 10 w/1/2 MPT x 1/2 MPT
5025 1/2" x 25' w/1/2" MPT x 1/2" MPT
5050 1/2" X 50' w/1/2" MPT x 1/2" MPT
54 1/2 x 1/2 Swivel Connector
7510P 3/4" x 10' w/3/4" MPT Optional Hose for Heaters
each end with Female over 375,000 BTU's
Swivel Adapter
7525P 3/4" x 25' w/3/4" MPT Optional Hose for Heaters
each end with Female over 375,000 BTU's
Swivel Adapter
7550P 3/4 x 50 x w/3/4 MPT each end with Female Swivel Adapter
ALL HOSES MEET OR EXCEED O.E.M.
SPECIFICATIONS. ALL HOSES UL APPROVED.
* With O.P.D. All tanks will ship UPS.
1/2 Hoses should be used
with low pressure Natural
Gas Heaters.
3/4 Hoses should be used
with high pressure Natural
Gas Heaters.
Part# Description BTU Content Wt.
C5 5# Tank 108,000 5
C10 10# Tank 215,000 10*
C20 20# Tank 430,000 20*
C30 30# Tank 645,000 28*
C40 40# Tank 860,000 37*
C50 50# Tank 1,080,000 45
C60 60# Tank 1,300,000 55
OPD Valves
In accordance with the April 1, 2002
National Fire Safety Standards
All propane cylinders 4# to 40# are
now required to contain overfill
protection devices
Propane Supplies
Phone: 800-362-6951 • Fax: 800-255-7985
www.phpdistribution.com