099494
TOO THIN
WELD
482-40
3/16" MIN
1/2"
1"
482-41
Safety Precautions
7. Do not drive power fasteners into steel base material less then 3/16" thick,
within 2" of a weld, within 1/2" of the edge or within 1" of another power fastener.
3"
3"
3"
482-39
6. Do not drive power fasteners into concrete less than three times as thick as the
intended fastener penetration, within 3" of the edge, within 3" of another power
fastener or within 3" of a failed power fastener.
3"
3X
1X
482-38
8. When fastening into masonry walls, always drive into horizontal mortar joints,
never into vertical mortar joints. Be careful. A poorly laid joint may permit too
much penetration, and/or unsatisfactory holding power.
OPERATING THE TOOL
1. Always hold tool perpendicular to work surface.
NO
YES
90˚