Remington HH-70T-KFA Troubleshooting Guide Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2013, Pinnacle Products International, Inc. Kerosene Forced Air Heater Users Manual
:LULQJ'LDJUDP
Maintenance
380335(6685(
While heater is operating, turn adjusting screw
clockwise to increase, counter-clockwise to
decrease pressure. Correct pump pressure is as
follows:
Model Number 3XPS3UHVVXUH
HH-45-KFA 3.0 PSI
HH-70T-KFA 4.0 PSI
HH-125T-KFA 5.0 PSI
HH-175T-KFA 7.5 PSI
HH-215T-KFA 9.0 PSI
Tolerance ± 10%
12==/(6
Nozzles should be cleaned or replaced at least
once per heating season. Contaminated fuel could
make this necessary immediately. To clean dirt
from nozzle, blow compressed air through nozzle
front. It may be necessary to soak the nozzle in
1-K kerosene to loosen any dirt particles.
Figure 18
Adjusting Screw
Pressure Valve
Figure 19
Nozzle
Nozzle Face
Burner Head
11
Figure 20: 45-KFA
Figure 21: 70T-KFA / 125T-KFA / 175T-KFA / 215T-KFA