Operation (Continued)
If the heater does not fire, the thermostat may be set too low.
Turn the Control Knob to a higher setting until heater fires. If
the heater still does not start, push Power Switch to “OFF”,
then back to “ON”. If heater still does not fire, see
Troubleshooting Guide on Page 15.
NOTE: The electrical components of this heater are protected by
a fuse mounted in the PC board. If the heater fails to fire, check
this fuse first, and replace if necessary. Also check the power
source to be sure that the proper voltage is being provided to the
heater.
TO STOP THE HEATER
Simply turn the Power switch to “OFF” position and unplug the
Power Cord.
TO RESTART THE HEATER
1. Wait ten seconds after shutting off heater.
2. Turn the Power Switch to “ON” position.
3. Be sure to follow all starting procedure precautions.
ELECTRICAL OUTLET
Shock Hazard!
- Never plug in an appliance with more than a 5 amp rating into
this outlet.
- Always keep outlet covered when not in use.
LONG TERM STORAGE
Drain Fuel Tank
For models HH-45/70T-KFA, drain fuel through the fuel cap open-
ing using an approved siphon. For models HH-125/175/215-KFA,
drain fuel through the Drain Plug at the bottom of the Fuel Tank.
2. To remove the Drain Plug (125/175/215),pull the Plug Grip
downward and remove seal head from drain hole in tank (See
Figure 11).
3. Using a small amount of kerosene, rinse and swirl the
kerosene inside of the Fuel Tank. Empty the tank fully.
4. To replace, push the drain head fully into the drain hole and
secure by pushing the seal cap fully into the head hole (See
Figure 12).
IMPORTANT: Never store leftover kerosene over the summer.
Using old fuel can damage your heater.
Page 8 Pinnacle Products International, Inc. Kerosene User’s Manual
WARNING
Figure 10. Electric Outlet Detail
Drain Plug
Fuel Tank
Seal Head
Head Flange
Head
Flange
Cap Flange
Seal Cap
Figure 11. Drain Plug Removal
Plug Grip
Drain Plug
Figure 12. Drain Plug Reinstall
Figure 9. Control Panel for all Models
Power Switch
Thermostat
Control Knob
Lamp
Room Temp.
Display(Except
HH-70T-KFA)
Models HH-70T / 125T / 175T / 215T-KFA
Model HH-45-KFA
Power
Switch
Electric Outlet (120v 5amp max
non fused)
Storage Drawer (except HH-
45 / 70T-KFA)
NEVER LEAVE HEATER
UNATTENDED WHILE BURN-
ING OR WHILE CONNECTED
TO A POWER SOURCE
Kerosene
Forced Air Heaters
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 55 56

Comments to this Manuals

No comments