NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2013, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual
Operation
Starting the Heater: (Ignition)
HH-70-SS-A:
1. Fill the tank with Kerosene or other approved
fuel until needle on fuel gauge points to “F”.
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong
(grounded) power source. You must use a
three prong (grounded) extension cord that is
at least 1.8 meters long and is a minimum of
14 AWG rating.
NOTE: On first ignition or after refueling,
you may hear a grinding sound just before
ignition. This is the fuel pump removing the
air from the fuel line. Your heater will start up
within seconds. If it does not start repeat
start-up procedures with fuel gauge reading at
least 1/2 tank.
NOTE: The electrical components of these
heaters are protected by a fuse mounted
in the PC board. If the heater fails to ignite,
check this fuse first and replace if necessary.
Also check the power source to be sure the
proper voltage is being provided to the heater.
1. Complete steps 1-3 above.
2. Push the power switch to the “ON” position.
The power indicator lamp will light and heater
will ignite. (See Figure 5)
Stoping the Heater: (Cool Down)
1. Turn the power switch to the “OFF” position.
Combustion will stop and the Cooling Cycle
will begin.
- HH-70-SS-A: approx. 3 mins
When the Cooling Cycle is complete the fan
will stop running and it will be safe to unplug
the heater.
NOTE: Unplugging the heater before the
Cooling Cycle has been completed may cause
overheating, possible damage to the heater and
heat plate.
Restarting the Heater:
1. Wait ten seconds after Cooling Cycle has
been completed.
2. Follow all start-up procedures above.
Electrical Outlet:
- Never plug an appliance with more than a 5
amp rating into this outlet (See Figure 6).
- Always keep outlet covered when not in use
Figure 5
Power Switch
6
DO NOT disconnect heater
from power source before
cooling cycle has been completed.
WARNING
Figure 6
Electrical Outlet
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 15 16

Comments to this Manuals

No comments