Maintenance (Continued)
SPARK PLUG:
Clean and re-gap every 600 hours of operation, or replace as
needed.After removing the Spark Plug, clean the terminals with a
wire brush. Re-gap the terminals to 0.140” (3.5mm).
PHOTOCELL:
The Photocell should be cleaned at least once per heating sea-
son or more depending on conditions.
Use a cotton swap dipped in water or alcohol to clean the lens of
the Photocell. Note the proper Photocell position as noted in
Figure 17 and Figure 18.
FUEL FILTER:
The Fuel Filter should be cleaned at least twice per heating sea-
son by rinsing it in clean 1-K kerosene. Contaminated fuel could
make this necessary immediately (See Figure 19).
NOTE: To remove the filter from models HH-45 / 70T-KFA, turn
filter 90
°
clockwise. To remove the filter from models HH-125T /
175T / 215T-KFA, turn filter 90
°
counter-clockwise.
Use of diesel may require additional maintenance.
Improper
maintenance can lead to poor combustion and soot
production.
Figure 19. Fuel Filter Replacement
Page 10 Pinnacle Products International, Inc. Kerosene User’s Manual
Figure 17. Photocell Positioning
Figure 18. Photocell Position for HH-45 / 70T-KFA
Figure 16. Spark Plug Replacement
Photocell
Photocell
Lens
Installing Photocell:
1) Incorrect
2) Correct
Photocell
Wire
HH-70T-KFA only
Circuit Board
Ignitor Wire
Burner Head
Spark Plug
Gap
Side Cover
Screw
Power Switch
Power Switch Wire
Circuit Board
Fuel Filter
Photocell Wire
Fuel Line
NEVER LEAVE HEATER
UNATTENDED WHILE BURN-
ING OR WHILE CONNECTED
TO A POWER SOURCE
Kerosene
Forced Air Heaters
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 55 56

Comments to this Manuals

No comments