Remington R300 User Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
14
106088
Operation
482-67
482-68
482-69
482-71
482-72
482-73
NOTE:
Failure to start with
the lowest power
level can result in
overdrive condition
and will result in
damage to tool
(see page 13).
1. Grasp muzzle and slide barrel forward rapidly until it stops. This sets piston into firing
position and opens the chamber.
2. Insert power fastener into muzzle of tool, head end first. Push the fastener until point
is even with end of tool. ALWAYS load the fastener first, then the power load.
3. Select the proper Remington Power Load and insert into the chamber until it stops
(see
Application Chart
on page 23).