FRIEDRICH DIGITAL CONTROL FEATURES CONTINUED
Instant Heat
Heat Pump Mode
Heat pump models will automatically run the electric heater to quickly bring the room up to temperature
when initially energized, then return to heat pump mode. This ensures that the room is brought up to
temperature quickly without the usual delay associated with heat pump units.
Even Heat Monitoring
The digital control monitors indoor conditions to ensure that the room temperature is within ve degrees
of the setpoint. If necessary the unit will cycle the electric heat to maintain the temperature. This feature
ensures guest comfort by delivering the heating benets of an electric heater while maintaining the
efciency benets of a heat pump.
Fan Cycle Control
The owner may choose between fan cycling or fan continuous mode based on property preference. (Note:
Even heat monitoring and quiet start/stop fan delay only operate in fan cycle mode). Fan continuous
mode is used to keep constant airow circulation in the room during all times the unit is ‘ON’. Fan cycle
will conserve energy by only operating the fan while the compressor or electric heater is operating.
Emergency Heat
Override
In the event of a compressor failure in heat pump mode the compressor may be locked out to provide
heat through the resistance heater. This feature ensures that even in the unlikely event of a compressor
failure the room temperature can be maintained until the compressor can be serviced.
Desk Control Ready
All Friedrich digital PTACs have low voltage terminals ready to connect a desk control energy management
system. Controlling the unit from a remote location like the front desk can reduce energy usage and
requires no additional accessories at the PTAC.
Indoor Coil Frost
Sensor
The frost sensor protects the compressor from damage in the event that air ow is reduced or low
outdoor temperatures cause the indoor coil to freeze. When the indoor coil reaches 30
°F the compressor
is diabled and the fan continues to operate based on demand. Once the coil temperature returns to 45
°F
the compressor returns to operation.
Ultra-Quiet Air System
The new Friedrich PD series units feature a indoor fan system design that reduces sound levels without
lowering airow and preventing proper air circulation.
High Efciency
The Friedrich PTAC benets quality components and extensive development to ensure a quiet, efcient
and dependable unit.
Single Motor
Friedrich’s single-motor design allows for enhanced outdoor airow and simplies the unit design without
the need for redundant components.
Rotary Compressor
High efciency rotary compressors are used on all Friedrich PTACs to maximize durability and
efciency.
Auxiliary Fan Ready
The Friedrich PTAC features a 24V AC terminal for connection to an auxiliary fan that may be used to
transfer air to adjoining rooms. Auxiliary fans can provide conditioning to multiple rooms without the
requirement of multiple PTAC units.
Aluminum Endplates
All Friedrich PTACs are built with .04” endplates made from aluminum as opposed to steel. The endplates
are typically the most susceptible area for corrosion and aluminum is far more resistant to corrosion than
even coated steel.
Seacoast Protection
Optional Seacoast protection is available to protect the outdoor coil from harsh environments. The
Friedrich Seacoast process includes dipping the entire outdoor coil in a 7-step coating process that
provides superior protection to only coating the ns of the coil.
Top Mounted Anti-
microbial Air Filters
All Friedrich PTAC return air lters feature an anti-microbial element that has proven to prevent mold
and bacterial growth in laboratory testing. PDXFT replacement lter kits feature the same anti-microbial
agent. All lters are washable and reusable and are easily accessed from the top of the unit without the
removal of the front cover.
Filtered Fresh Air
Intake
Friedrich PTAC units are capable of introducing up to 70 CFM of outside air into the conditioned space.
The outdoor air passes through a washable mesh  lter to prevent debris from entering the airstream.